2.- Dosage pump pH corrector. (01285)
Not fixed to the panel:
3.-Electrical valve 1" 230V ac (14908R002)
14. POWER PLANT DECRIPTION
1 . -DISPLAY LCD: Back lightened display that shows the pH value and its set point value. It also shows the mV value and its set
point value. The arrow to the right of the set point value shows if an pH enhancer is being used when it is upwards and it is
downwards, shows that a pH reducer
2 . - 4 ARROW KEYBOARD: We can move in the display through these arrows when we enter the programme. Pressing the four
buttons (20, 2b, 2c and 2d) at a time, you can see the equipment version and a manufacturing code.
3.- ENTER BUTTON: It is used to enter the programme and for the programme itself.
4 .- VAL BUTTON: It is used to validate.
5 .- ESC BUTTON: It is used to go out of the programme.
6.- pH PILOT: When it is enlighted, it shows that the pump relay is switched on.
7.- –Cl PILOT: When it is enlightened, it shows that the Chlorine pump o valve motorised o valve electrical relay is switched on.
15. POWER PLANT DIAGRAM
16. STARTING, ADJUSTING AND CALIBRATION
It is advisable that before the starting of the Control Minor we have the water between 7 - 7.6 units of pH and 1 - 1,5 ppm Cl
or 2-3 ppm Br.
pH
pH
2
1
8
3
Ref.16642R0100-gb-R04