8.
FUNCTION LOGICS
LOGIC
Open
Close
Status
(pulse)
(maintained)
Closed
Opens
/
Opening
/
Closes
Open
/
Closes
Closure
Opens
Closes
Locked
Opens
Closes
LOGIC
Open
Close
Status
(pulse)
(pulse)
Closed
Opens
/
Opening
/
Closes
Open
/
Closes
Closure
Opens
/
Locked
Opens
Closes
LOGIC
Open
Close
Status
(maintained)
(maintained)
Closed
Opens
/
Opening
Opens
Locks
Open
/
Closes
Closure
Opens
Closes
Locked
Opens
Closes
LOGIC
Open
Close
Status
(pulse)
(pulse)
Closed
Opens
/
Opening
Locks
Closes
Open
Closes
Closes
Closure
Locks
/
Restarts in
Locked
opposite
Closes
direction
B/C
Stop
Safety
Disables
/
Open and Close
Locks
/
Disables
Disables
Open and Close
closing
Locks
Opens
Disables
Disables
Open and Close
closing
B
Stop
Safety
Disables
/
Open and Close
Locks
/
Disables
Disables
Open and Close
closing
Locks
Opens
Disables
Disables
Open and Close
closing
C
Stop
Safety
Disables
/
Open and Close
Locks
/
Disables
Disables
Open and Close
closing
Lock
Locks
Disables
Disables
Open and Close
closing
EP
Stop
Safety
Disables
/
Open and Close
Locks
/
Disables
Disables
Open and Close
closing
Locks
Opens
Disables
Disables
Open and Close
closing
EC DECLARATION OF CONFORMITY
Manufacturer :
FAAC S.p.A.
Address:
Via Benini, 1 - 40069 Zola Predosa BOLOGNA - ITALY
Declares that:
540BPR control board,
conforms to the essential safety requirements of the following
directives:
73/23/EEC and subsequent amendment 93/68/EEC.
89/336/EEC and subsequent amendment 92/31/EEC and 93/68/
EEC
Additional note:
This product underwent tests in a typical uniform configuration (all
products manufactured by FAAC S.p.A.).
Bologna, 01 January 2006
Open
Status
(pulse)
Opens and
Closed
closes after
pause time
Opening
Locks
Pause
Locks
Closure
Opens
Locked
Closes
Open
Status
(pulse)
Closed
Opens
Completes
Opening
/
opening and
then closes
Open
/
Closure
Opens
Locked
Opens
Open
Status
(pulse)
Opens and closes
Closed
after pause time
Opening
/
Recharges
Open
pause time
Closure
Opens
Locked
Opens
The Managing Director
A. Bassi
6
LOGIC
AP
Close
Stop
(pulse)
Disables
/
Open and Close
Closes
Locks
Closes
Locks
/
Locks
Disables
Closes
Open and Close
LOGIC
P
Close
Stop
(pulse)
Disables
/
Open and Close
Locks
Disables
Closes
Open and Close
/
Locks
Disables
Closes
Open and Close
LOGIC
A
Close
Stop
(pulse)
Disables
/
Open and Close
Completes
Locks
opening and
then closes
Closes
Locks
/
Locks
Disables
Closes
Open and Close
Safety
/
/
Repeats
pause
Opens
Disables
closing
Safety
/
/
Disables
closing
Locks and
closes on
release
Disables
closing
Safety
/
/
Recharges
pause time
Opens
Disables
Close