Autoranging

Tru-Test indicators are usually set to autorange. This means that the display resolution automatically changes to
coarser increments when the weight reaches the equivalent of 200 or 250 times the next coarser division size.
This better reflects the actual accuracy of the scale.
The weight is still displayed in kilograms or pounds, it is only the resolution (precision) which changes at higher
loads.
Autorange (load bar pair)
Weight range
Resolution
0 to 50 kg
0.1 kg
50 to 100 kg
0.2 kg
100 to 200 kg
0.5 kg
200 kg to 500 kg
1 kg
500 kg to 1000 kg
2 kg
1000 kg to capacity
5 kg
The live capacity of the scale is usually a round multiple of the base resolution, for example:
3000 x 0.5 kg = 1500 kg.
Capacities
Fine mode may be disabled for particular markets and models.
The load bar codes given in the table can be displayed using the service/setup functions on the indicators.
For further details see your Indicator User Manual.
Cell Code
Type
16
4x HD series
(load bar adaptor cable)
94
HD series (pair)
96
HD series (single)
Note: The load cell code is used to identify which type of load bars are connected to the indicators.
8
Fine mode
Fine mode
Capacity
6000 kg
3000 kg
1500 kg
Weight range
Resolution
0 to 100 lb
0.2 lb
100 to 200 lb
0.5 lb
200 to 500 lb
1 lb
500 lb to 1000 lb
2 lb
1000 lb to 2000 lb
5 lb
2000 lb to capacity
10 lb
(13,000 lb)
(6600 lb)
(3300 lb)
Fine mode
Fine mode
Tabla de contenido
loading

Este manual también es adecuado para:

Hd800Hd850Hd1010

Tabla de contenido