INTRODUCTION

Door Access

Disconnect power BEFORE making electrical connections. Below is an example of a wiring setup for door access. Door access can be
wired to Door 1 or 2.
NOTE: Power Supplies shall be UL Listed Commercial 294 or 603 power limited
output Power Supplies.
RFID ANTENNA
NOTE: Power supply for
RFID antenna is not provided.
DO NOT use the power supply
for the door controller.
PRIMARY RELAY
MAGLOCK
Model MG1300
Power for Maglock
(Not Provided) DO
NOT use the power
supply for the
controller
Use 18-22 AWG
For DC Power:
Install a 1N4005 diode
or equivalent
DOOR STRIKE
Model HES(RS) 1006CLB(R)
Use 18-22 AWG
For DC Power:
Install a 1N4005 diode
or equivalent
AUXILIARY RELAY
ALARM BYPASS
COMMON
NORMALLY OPEN
NOTE: DO NOT run high voltage power within the CAP2D enclosure. This
configuration has not been evaluated by UL. Use UL Listed Power Limited
Power Supplies and UL Listed Isolation Relays.
PRE-INSTALL
WIRING
WIEGAND
OR
For AC Power:
Install a Siemens
S10K30MOV
(Metal Oxide Varistor)
or equivalent
COMMON
NORMALLY CLOSE
OR
For AC Power:
Install a Siemens
S10K30MOV
(Metal Oxide Varistor)
or equivalent
NORMALLY OPEN
COMMON
Power for Maglock
(Not Provided) DO
NOT use the power
supply for the controller
LIGHT
Low
Voltage
Power
Supply
OR
LOAD
Isolation
Relay
LINE
NETWORK
KEYPAD
OR
NOTE: For KPR2000 keypad
wire the pink and black (ground)
wires together.
REQUEST TO EXIT
PROXIMITY
SENSOR
NO
NC
COM
NO
COM
NO
16
ACCESS CONTROL
NOTES:
• The length of the unshielded
wires should be kept to a minimum
to avoid electrical noise.
• When extending the reader connection,
the shield wire must be connected to an
READER
earth ground bus, but should NEVER be
connected at the reader.
PUSH
BUTTON
OR
NO
COM
COM

INSTALL