Technical Data
Input
•
380-480 VAC 3PH auto select
Nominal voltage:
•
Power factor (PFC):
as required to meet EN61000-3-2
Output
•
24V (22.5-28.5VDC Adj.)
Nominal voltage:
•
Power boost:
2x nominal current for 2 sec.
•
Holdup time:
> 16ms at Full Load (25˚C)
•
Tolerance:
< ±2 % overall
Line regulation
<0.5%
Load regulation
<0.5%
Time & temp. drift
<1%
•
Initial voltage setting:
24.5V ± 1%
•
< 50mVpp
Ripple:
•
> 35V
Power back immunity:
•
Switch Selectable
Parallel Operation:
•
Over voltage protection:
< 33VDC
Standards, Certifications
EMC
Emissions
EN 61000-6-3, Class B EN55011, EN55022 Radiated
Conducted including Annex A
Immunity
EN 61000-6-2, EN61000-4-2 Level 4, EN61000-4-3 Level 3,
EN61000-4-6 Level 3, EN61000-4-4 Level 4 input and level 3
output. EN61000-4-5 Isolation class 4, EN61000-4-11,
Transient protection according to VDE 0160/W2 over entire
load range.
Approvals
EN60950, UL508 Listed, cULus, UL 60950, cURus, CE (LVD
73/23 & 93/68/EEC), (EMC 89/336 & 93/68/EEC). EN61000-
3-2, EN60079-15 (Class 1, Division 2 hazardous location,
Groups A, B, C, D w/ T3 temp class up to 60˚C Ambient.)
SEMIF47 Sag Immunity.
Environmental Data
Ambient temperature
Storage/Shipment
-25˚C...+85˚C
Full nominal load
-10˚C...+60˚C
Derated
+60˚C...+70˚C
Degree of protection:
IP20 (EN60529), Protect the unit from
moisture (and condensation)
Installation
Fusing
Input
Internally fused.
Output
Outputs are capable of providing high currents for short
periods of time for inductive load startup or switching.
Mounting
Simple snap-on to DIN TS35/7.5 or TS35/15 rail system.
Unit should handle normal shock and vibration of industrial
use and transportation without falling off the rail.
Connections
Input: screw terminals, connector size range: 16-10AWG
(1.5-6mm2) for solid conductors.
Output: Two terminals per output, connector size range: 16-
10AWG (1.5-6mm2) for solid conductors.
This equipment is suitable for use in Class 1, Division 2, Groups A,B,C,D or non-
hazardous locations only
WARNING – EXPLOSION HAZARD – Substitution of components may impair suitability
for Class 1, Division 2.
WARNING – EXPLOSION HAZARD – Do not disconnect equipment unless power has
been switched off or the area is known to be non-hazardous
DIN Rail Mounting
Montaje en Riel DIN
Monture du Rail DIN
Snap on the DIN Rail:
Atorar en en Riel DIN:
Poser le Rail DIN:
1. Tilt unit as
1. Incline la unidad
1. Faire pivoter
illustrated
como se ilustra
2. Put it onto the DIN
2. Póngala sobre el Riel
Rail
DIN
2. Poser sur le Rain
3. Push downwards
3. Empuje hacia abajo
until stopped
hasta que se
3. Enfoncer jusqu'à
detenga
4. Push at the lower
front edge to lock
4. Empuje de la parte
4. Appuyer sur le bord
baja del frente para
asegurar
5.
Shake the unit
slightly to ensure
5.
5.
that the unit is
Mueva la unidad
secure
ligeramente para
verificar está segura
SDN Series
Power Supplies
Technical Services
USA
SDN5-24-480
International
www.solaheviduty.com
Rev. 0 (October 10, 2003)
l'appareil comme
illustré
DIN
arrêt
inférieur pour fixer
Vérifier que l'appareil
est bien fixé
(800) 377-4384
(847) 268-6000
P/N: A272-101