Beninca MATRIX Manual Del Usuario página 11

Ocultar thumbs Ver también para MATRIX:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
Terminal No.
Function
1-2
Power supply
3
GND
4-5
Aerial
6-7
RX 2° Ch
8-9
24Vac
SCA o
10-11
Service light
12-13
PHOTO TEST
14
COM
15
OPEN
16
CLOSE
17
Step-by-Step
18
PED
19
COM
20
STOP
21
PHOT O
22
SWO
23
SWC
24
PHOT C
25-26
DAS
27-28-29
Motor
27-30
Capacitor
31-32
Blinker
1) Cut-off power supply.
2) Manually release the wing, move it to approx. half-stroke and lock it again.
3) Reset power supply.
4) Send a step-by-step control signal by pressing the button or the remote control key.
5) The wing should start an opening movement. If this is not the case, invert the movement wires (27< >29) of the motor and the
limit switch wires SWO-SWC (22< >23).
6) Cut-off and restore power supply.
The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting
the desired values in the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the software
release.
The CP.BULL-RI and MATRIX control units are equipped with a built-in radio module to receive both
fixed code and variable code control signals with a frequency of 433.92MHz, able to store up to 64 different codes in memory.
The RADIO menu and the 2Ch and CVAR logic are available in these control units only.
The CP.BULL and MATRIX-RE control units are equipped with connector for extractable receiver.
MATRIX/CP.BULL Control Unit
INPUT/OUTPUT FUNCTIONS
Description
Input, 230Vac 50Hz (1-Phase/2-Neutral)
Connection to ground (compulsory)
Connection of the insertable radio receiver card (4-signal/5-display).
Output, second radio channel of the receiver. N.O. voltage-free contact.
This output is not available in CP.BULL-RI and MATRIX control units with built-in receiver.
Output: power supply of accessories, 24Vac/500mA max.
Normally Open (N.O.) free contact. Configuration like SCA (open gate warning LED) or timed
service light (see SERL Logic).
In CP.BULL-RI and MATRIX control units with built-in receiver, this contact can be preset as
output of second radio contact (see 2ChLogic).
N.O. free contact. It is used to power photocell transmitters in TEST operating mode.
See diagram "Connection of tested safety devices" and TST1 and TST2 Logic.
Common for control inputs.
Input, OPEN push-button (N.O. contact).
Input, CLOSE push-button (N.O. contact)
Input, step-by-step push-button (N.O. contact)
Input, pedestrian push-button (N.O. contact). It controls the partial opening. Configuration is
through parameter TPED. When TCA time has elapsed (if activated) a closure control signal
is sent.
Common, for limit switches and safety devices
Input, STOP push-button (N.C. contact)
Input, (N.C. contact) for safety devices (e.g. photocells).
In the closing phase: the contact opening causes the motor stop. Common: when the photo-
cell is released, the motor inverts the movement direction (open).
In the opening phase: the contact opening causes the motor stop. When the photocell is
released, the motor re-starts the opening operation.
Input, OPEN limit switch (N.C. contact)
Input, CLOSE limit switch (N.C. contact)
Input (N.C. contact) for safety devices (e.g. photocells).
In the closing phase: Configuration through PHTC Logic.
In the opening phase: Configuration through PHTC Logic.
Input, safety edge
Resistive edge: "DAS" Jumper closed
Mechanical edge: "DAS" Jumper open
When the edge is activated, the gate movement is stopped and reversed for about 3s.
If the edge is not in use: "DAS" Jumper open, 25-26 terminals are short-circuited.
Connection of motor 230Vac - single-phase:
27-Phase/28-Common/29-Phase
Connection of capacitor
Connection of blinker, 230Vac 40W max.
To check connections:
Programming
11
Tabla de contenido
loading

Este manual también es adecuado para:

Cp.bullMatrix-reCp.bull-ri

Tabla de contenido