• 40 AMP Power Supply Wiring Diagram
CUSTOMER CONNECTION
INCOMING POWER
1PH, 100-240V (-15%/+10%)
8.6 / 4.5 AMPS (16/9 AMPS PEAK INRUSH)
GND
NEU
L1
NOTE:
Terminals Seperated to
Clarify Wiring Details
FIGURE 9A
CUSTOMER CONNECTION
INCOMING POWER
3PH, 380-480V (-15%/+20%)
1.65 / 1.35 AMPS (4.5 AMPS PEAK INRUSH)
GND
L3
L2
L1
Terminals Seperated to
Clarify Wiring Details
FIGURE 9B
MODEL E24 AND E24EZ POWER SUPPLY
INPUT
PART NO.
PHASES
VOLTAGE
EB-000004
100-240
EB-000006
380-480
120VAC
40AMP
Parallel Use
Single Use
460VAC
40AMP
Adjust
Parallel Use
Single Use
Overload
DC ok
Shut-
Down
L1 L2 L3
INPUT
INRUSH
AmPS
AmPS
VOLTAGE
1
8.6/4.5
16/9
3
1.65/1.35
4.5
24-
24V
DC ok
Overload
DC ok
13
14
15
16
NOTE: Only turn off incoming power to the power supply unit under E-
Stop conditions or maintenance reasons. A run contact must be used to
OUTPUT
OUTPUT
control starting and stopping of an E24 transportation type conveyor.
AmPS
nOta: sólo se apague la alimentación de entrada a la unidad de sumi-
24
40
nistro de energía en condiciones de parada de emergencia o por ra-
24
40
zones de mantenimiento. Un contacto de marcha debe ser utilizada
para controlar el arranque y la parada de un e24 tipo de transporte del
transportador.
9
For PNP Control Operation
Funcionamiento del Control PNP
WHT/BLU
BLU
ORG
YEL
For PNP Control Operation
Funcionamiento del Control PNP
WHT/BLU
BLU
ORG
YEL
A run contact must be
used to control starting
and stopping of an E24
transportation type
conveyor.
Un contacto de
marcha debe ser
utilizada para controlar
el arranque y la parada
de un E24 tipo de transporte
del transportador.
BLK (COM)
RED (+24)
WHT/BLU
BLU
ORG
YEL
A run contact must be used
to control starting and
stopping of an E24
transporation type conveyor.
Un contacto de
marcha debe ser
utilizada para controlar
el arranque y la parada
de un E24 tipo de transporte
del transportador.
BLK (COM)
RED (+24)
WHT/BLU
BLU
ORG
YEL