Test Installation; To Check Heat - Filtrete 3M-22 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Test Installation

Follow these procedures to verify you have
correctly installed the 3M-22.
TO CHECK FAN (If you connected the G wire):
Move the fan switch to ON. Verify that air is blowing from the
system. Move the fan switch back to AUTO.

TO CHECK HEAT

Set the mode switch to HEAT.
+
Press the
button and raise the target temp to 90
Verify that heat is blowing from the system.
Return mode to OFF.
If you have a heat pump, leave in off for 4 minutes before checking COOL.
TO CHECK COOL (do not operate AC if the outside temperature is below 65
Set the mode switch to COOL.
-
Press the
button and lower target temperature to 50
Allow the system 5 minutes to respond.
Verify that cool air is blowing from the system.
Return mode to OFF.
FAN
F. Allow the system 2 minutes to respond.
o
F.
o
MODE -
HEAT-OFF-COOL
F)
o
11