When the sensor is activated (open –
it is raining) programs keep on proceeding normally but valve outputs are deactivated.
- If rain starts when irrigation is processing, the valve currently working is stopped (but programs keep on proceeding)
- If rain starts when irrigation is closed, valve outputs are deactivated and despite programs are processing,
irrigation does not start as scheduled.
- If sensor state comes back to normal state (closed) during planned irrigation, the current valve starts for
the remaining duration in the current program.

3. Flow Sensor Settings

Available on TBOS-II
TM
- When connected to a TBOS-II Controller,
from the Main Menu select "Check programs",
select "Sensor parameters"
- 3 screens allow to set-up all configurations:
WARNING: The user sets-up a settling time (1 to 10 minutes) – Corresponds to the time during which the over
consumption has to be observed before the program gives the alert.
If the consumption is above the threshold for a duration exceeding the settling time set-up by the user, then
an over-flow alert is launched and prevent irrigation until the alert clearance by user.

4. State switch of a flow sensor

The reactions for the state switch of a flow sensor are the alert and the selection of none affected valves.
Only IQ Software is able to display flow count.
Please read the HELP Section of IQ
offset,...)
30
centralized on IQ V2 only.
software to set up your sensor (settings, alert thresholds, K factor and
TM
Installation Schematic of a RSD-Bex