STEP 4
Calibrate the system
This step is critical to ensuring the system responds appropriately to
terrain. Calibration only needs to take place once, unless components are
replaced, in which case the system requires recalibration.
The Live Valve system will not function properly unless it is calibrated
according to the sequence below. Verify that the professional bicycle
mechanic has completed the calibration sequence correctly. It is ok to
repeat calibration.
1.
Press the Power button to turn the system on.
2. Make sure the bike is upright, still, and on a level surface.
3. Press and hold the Setting Selector button for 15 seconds.
4. Release the Setting Selector button once the red OFF LED illuminates.
5. Once a green LED illuminates, press the Power button once and release it.
6. A green LED will flash 3 times to indicate the calibration process is complete.
10