Indoor Unit - Electrolux EXH09HL1W Manual Del Usuario

Bomba de calor inversor split
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

18
www.electrolux.com

Indoor unit

Installing the mounting plate
1. Install the mounting plate
horizontally.
2. Fix the mounting plate to the wall
with screws. Make sure that the
mounting plate is fixed firmly enough
to support approximately 60 kg. The
weight must be evenly shared by
each screw.
Drill piping hole
1. Slant the piping hole (Ø 55 mm) on
the wall slightly downward to the
outdoor side.
2. Insert the piping-hole sleeve into
the hole to prevent damage to the
connection piping and wiring.
Installing the drain hose
1. Connect the drain hose to the outlet
pipe of the indoor unit. Bind the joint
with rubber belt.
2. Put the drain hose into the insulating
tube.
3. Wrap the insulating tube with wide
rubber belt to prevent the insulating
tube from shifting. Slant the drain
hose slightly downward for smooth
drainage of the condensate water.
NOTE
connected reliably with the sleeve
outside the outlet pipe. The
drain must be slanted downward
slightly without distortion, bulge or
fluctuation. Do not put the outlet of
the drain hose in water to prevent the
drain hose from freezing.
Electrical wiring indoor unit:
1
Nr.
1
2
3
4
CAUTION
there is no short circuit. Incorrect
wiring can cause malfunction.
1. Open the front panel.
2. Remove the wiring cover.
3. Fix the mains cord to the terminal
board (as shown).
4. Guide the mains cord through the
hole at the back of the indoor unit.
5. Install the cord anchorage and
wiring cover.
6. Close the front panel.
NOTE
indoor unit and the outdoor unit
must be connected by a qualified
electrician.
wire slightly to confirm whether it's
firm or not.
connections are properly grounded to
prevent electric shock.
2
3
4
Colour
Blue (neutral)
Black
Brown
Yellow (ground)
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Exh12hl1wEph09mliwEph12mliw

Tabla de contenido