Carefully examine the carton for damage before opening. If the carton is damaged, notify the shipping
company immediately.
Install Casters (Cold Front 300 only):
1. Locate the package of four (4) casters and remove from box.
2. Lay box on its side and carefully open bottom of box. DO NOT STAND BOX UPSIDE DOWN.
3. Install the four casters.
4. Stand cooler up on casters and remove box.
The cooler has been factory tested and is ready to use. Place the cooler on level ground with the casters locked
to prevent inadvertent movement.

Connecting the water supply

The cooler comes equipped with a female garden hose water source connection. Use a standard garden hose
(not provided) to connect the water supply to the cooler.
Do not connect to any water source where water pressure exceeds 120 PSI. This will cause permanent
damage to the cooler.
Connecting the electrical supply
The cooler should be plugged into a fused or breaker-protected circuit. Refer to Table 1 for circuit size
requirements. Cold Front 500 models cannot be connected to a GFCI outlet.
Amperage and Circuit Requirements
Model
Cold Front 300
Cold Front 400 and 401
Cold Front 500
Do not exceed the amperage ratings of the extension cord. Undersized extension cords create excessive
drops in voltage, causing the electric motor to generate excess heat. This results in inefficient motor
operation and premature motor failure and will void the warranty.
Three-Conductor Heavy Duty Extension Cord Requirements
Cord
Length
0–50 ft (0–15 m)
50–100 ft (15–30 m)
2

ASSEMBLY AND SETUP

Volts +/- 10%
120 V
120 V
120 V
16 GA
13 A
10 A
WWW.BIGASSFANS.COM
IMPORTANT
CAUTION
IMPORTANT
Frequency
60 Hz
60 Hz
60 Hz
CAUTION
Cord Size
14 GA
18 A
13 A
© 2020 DELTA T LLC
ALL RIGHTS RESERVED.
Table 1: Electrical Requirements
Min. Circuit Size
15 A
15 A
25 A
Table 2: Cord Size Requirements
12 GA
25 A
18 A
Running Amps
4.1 A
8.0 A
16.5 A
10 GA
30 A
25 A