➢ ➢ Agitator thermal protector trips to prevent agitator motor from overheating.
➢ ➢ Agitator thermal protector may trip if vacuum is operated with agitator rotating
and hose removed from tool holder.
➢ ➢ To correct problem, turn off and unplug vacuum.
➢ ➢ Wait approximately thirty (30) minutes and plug vacuum in and turn back on.
Agitator Overload
Protector
Protección de sobrecarga
del agitador
Bouton du protecteur
contre surcharges

Agitator Thermal Protector

Agitator Overload Protector

- 18 -
➢ ➢ The agitator motor has built-in
protection from motor damage
should the agitator jam.
➢ ➢ If agitator slows down or stops, the
agitator overload protector will shut
off the agitator motor.
➢ ➢ The suction motor continues to run.
➢ ➢ To correct problem, turn off and
unplug vacuum, remove obstruction.
➢ ➢ Press agitator overload protector
reset button to reset agitator.