Troubleshooting Guide - Parker Pneudri Maxi MX102 Guia Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 111
MX 102 - MX110 User Guide
6.

Troubleshooting guide

In the unlikely event that a problem occurs on the equipment, this troubleshooting guide can be used to identify the probable cause
and remedy.
Troubleshooting should only be attempted by competent personnel. All major repair, and calibration work should be
undertaken by a domnick hunter trained, qualified and approved engineer.
Warning
Problem
Poor dewpoint identified by water in the
downstream piping and equipment.
High pressure drop resulting in low pressure
gauge readings or intermittent operation of
the downstream equipment.
Interruption of the air supply downstream
leading to a rapid loss of system pressure.
Possible cause
Dryer is operating outside of its sizing
criteria.
Bypass valve is open.
Dryer has recently been started.
The condensate is not being drained.
Regeneration column pressure > 350mbar.
Timer malfunction.
Valve malfunction.
Desiccant is approaching the end
of its useful life.
The pre / after filtration is approaching the
end of its operational life.
The dryer is being overflowed or is
operating at a reduced system pressure.
An isolation valve is partially closed.
Pressure loss from the system.
The dryer tripped due to power
supply interruption to the dryer.
The compressor tripped due to power
supply interruption to the compressor.
Isolation valve closed
Compressor switched off.
Fault shutdown event.
14
Action Required.
Check actual inlet parameters and
environmental conditions against the
values quoted at the time of sizing.
Check bypass valve is fully closed.
Allow time for the system to "dry down"
Check the condensate drain(s) for faults.
Check the drain hoses are free from kinks and
obstructions.
Ensure that the drain isolation valves
are fully open.
Replace the exhaust silencers.
Contact domnick hunter approved
service agent.
Contact domnick hunter approved
service agent.
Contact domnick hunter approved
service agent.
Check and replace.
Check actual inlet conditions against the values
quoted at the time of sizing.
Check the position of all the isolation valves.
Check the system for leaks.
Ensure that the drain cocks and
pressure relief valves are closed.
Check that the dryer "POWER ON"
indicator is illuminated. If it is not
check the isolator and fuses.
Check that the compressor "POWER
ON" indicator is illuminated. If it is not
check the isolator and fuses.
Check the position of the isolation valves.
Check the compressor.
Check the dryer fault indicators.
Tabla de contenido
loading

Este manual también es adecuado para:

Pneudri maxi mx110

Tabla de contenido