INSTALLATION MANUAL
DGA
Cast aluminium Digicode
- wait a few seconds, one beep is emitted. The green LED lights off. Unshort the wires.
3] The keypad is reset to the factory default values.
SETTING CODE LENGTH
1] Enter the master code twice (12345 default value master code) :
- the red LED lights on to confirm entry in programming mode
2] Press A4 to program the code length:
- the green LED lights on during 1 second,
- press 4, 5 or 6 to enter the code length,
- the green LED lights on during 1 second to confirm programming of the code length.
3] Enter A5 to modify the master code:
- the green LED lights on during 1 second,
- enter the new 4 or 5 or 6-digit master code,
- the green LED lights on during 1 second to confirm programming of the new master code.
4] Press B to exit from programming mode:
- the red LED lights off to confirm exit from programming.
The red LED flashes 4 times to indicate a data computing error
Master code or user code: 12369
When changing to 4-digit code: enter 2369
When changing to 6-digit code: enter 012369
It is recommended to program the codes in 6-digits and then modify the code length.
CHANGING THE MASTER CODE
1] Enter the master code twice (12345 default value master code):
- the red LED lights to confirm entry in programming mode.
2] Press A5:
- the green LED lights on during 1 second,
- enter the new master code (according to the code length set up),
- the green LED lights on during 1 second to confirm programming.
3] Press B to exit from programming mode. The red LED lights off to confirm exit from programming.
ADDING USER CODES
Group 1: from user number 00 to user number 59, relay 1
Group 2: from user number 60 to user number 99, relay 2
12
cdvigroup.com
Self Contained
®