Teka DA Serie Manual De Instrucciones página 18

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Manual DA.qxd
11/04/2003
Accesories supplied
1
150/125 mm reduction.
1
Anti-recoil valve.
2
Support for tubecover.
2
Wall supports.
4
Screws M4x12.
6
Wall plugs (Ø8 x 40).
6
Long bolts (Ø5 x 45).
4
Wall plugs (Ø6 x 30).
4
Long bolts (Ø4 x 30).
2
Ø6.4 x Ø18, washers.
2
Ø6.4 x Ø12, washers.
2
Screws (Ø3.9 x 13).
2
Clips.
Installation
Fig. 1 (Page 19)
On installing the kitchen hood make sure
that the Safety Instructions set out on page
14 are complied with.
To obtain optimum performance, the external
duct must not be more than FOUR METRES
LONG, have no more than two 90° angles and
its diameter must be at least Ø120.
1) Using the attached template, trace and drill
the points for fitting the wall plugs onto the wall
(P) (Ø8 x 40) and (J1) (Ø6 x 30).
2) Centre the support (H) around the point
marked (J1); trace and drill the fixing point for
the wall plug (J2) (Ø6 x 30).
3) Attach the Supports (O) to the wall using the
long bolts (Q) (Ø5 x 45) and the support (H)
with the long bolts (I) (Ø4 x 30), as in figure 1.
4) Hang the kitchen hood onto the mounted
supports (O). Straighten the appliance by
tightening the long bolts (L) (M4 x 12).
5) Trace the location of the long bolts (S) (Ø5 x
45).
6) Take the kitchen hood off.
7) Drill into the wall and fit the wall plugs (R)
18
18:34
PÆgina 18
(Ø8 x 40).
8) Hang the kitchen hood; tighten the screws
(M) (M4 x 12) with the washers (A3) (Ø6.4 x
Ø12) and the long bolts (S) (Ø5 x 45) with the
washers (T) (Ø6.4 x Ø18).
9) Mount the tubecovers, attaching the lower
one to the support (H) as per the detail in figure
1. Lift the upper tubecover up to the desired
height and mark its shape on the wall. Remove
the tubecovers.
10) Fit the clips (F) to the support (C).
11) Centre the support (C) around the shape
marked; trace and drill the fixing points for the
wall plugs (E) (Ø6 x 30). Attach the support (C)
with the long bolts (D) (Ø4 x 30).
12) Fit the part (A) if the inner tube (not
supplied) is Ø150 or (A) + (B) if it is Ø120.
13) Attach the inner tube with a clamp (not
supplied) to (A) or (B) as the case may be.
14) Once the inner tube is fitted, fit the lower
tubecover around the extractor fan outlet and
attach the upper tubecover with the screws (G)
(Ø3.9 x 13).
When exterior gas extraction is not possible,
then the kitchen hood may be set to purify the
air by recycling it through active carbon filters.
The active carbon filters have an active life of
between three to six months, depending on
the individual conditions of use. These filters
cannot be washed nor regenerated. They must
be replaced once their useful life comes to an
end.
Fig. 2 (Page 19)
1) Fit the nut-supports (F) onto the body of the
kitchen hood.
2) Attach the supports (B) with the screws (E)
(M4 x 12) onto the nuts (F).
3) Mount the carbon filters (A) introducing the
anchorages into the grooves of the supports
(B).
4) Remove the tubecovers (H). Fit the nut-
supports (G) to the diffuser (C).
5) Fit the diffuser (C) into the inside of the lower
tubecover with the screws (D) (M4 x 12). Mount
the tubecovers (H).
Active charcoal filters (Optional)
Tabla de contenido
loading

Este manual también es adecuado para:

114321da134321da

Tabla de contenido