Installation Guidelines

• Where a wall or other obstacle is in the path of the outdoor unit's intake or exhaust airflow, follow the installation guidelines below.
• For any of the below installation patterns, the wall height on the outlet side should be 47-1/4 inch (1200mm) or less.
09/12 class
Wall facing one side
More than
1-15/16 (50)
Walls facing three sides
More than
1-15/16 (50)
18/24 class
Wall facing one side
More than
3-15/16 (100)
Walls facing three sides
More than
1-15/16 (50)

Outdoor Unit Installation

1.

Installing the outdoor unit

1) When installing the outdoor unit, refer to "Precautions for Selecting the Location" and the "Outdoor Unit Installation Drawings".
2) If drain work is necessary, follow the procedures below.
5
More than
3-15/16 (100)
47-1/4
(1200)
or less
Side view
More than 5-7/8 (150)
More than
11-13/16 (300)
Top view
More than
13-3/4 (350)
47-1/4
(1200)
or less
Side view
More than 3-15/16 (100)
More than
13-3/4 (350)
Top view
Walls facing two sides
More than
3-15/16 (100)
More than
1-15/16 (50)
unit: inch (mm)
Walls facing two sides
More than
3-15/16 (100)
More than
1-15/16 (50)
unit: inch (mm)
More than
5-7/8 (150)
More than
1-15/16 (50)
Top view
More than
13-3/4 (350)
More than
1-15/16 (50)
Top view