Cleaning, Care and Maintenance

Switch off the Power at the mains prior to cleaning.
Do not use abrasive cleaning agents. These can leave harmful residues.
Always wipe dry after cleaning
A Buffalo agent or qualified technician must carry out repairs if required.
Trouble Shooting
Problem
Diagnosis
Unit does not
Power off
operate
Sensing distance too short
Sensing device damaged
No hot air
Heater faulty
Motor damaged

Technical Specifications

Model
Voltage
GD847
230v 50hz

Electrical Wiring

This appliance is wired as follows:
Live wire (coloured brown) to terminal marked L
Neutral wire (coloured blue) to terminal marked N
Earth wire (coloured green/yellow to terminal marked E
This appliance must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible.
5 |
P a g e
Remedy
Check power
Call Buffalo agent or qualified engineer
Call Buffalo agent or qualified engineer
Call Buffalo agent or qualified engineer
Call Buffalo agent or qualified engineer
Power
Current
2500w
11.5A
Dimensions
H X W X D (mm)
200 x 275 x 230
Weight (Kg)
6