RZ_CLASSIC_D_F_I_E_CLASSIC_D_F_I_E 04.06.13 11:25 Seite 33
What can be done...
if the drive shaft of your appliance no longer rotates?
When you have not used your appliance for some time, the drive
shaft may get stuck due to minute foodstuff residues which have
hardened and are now gumming up the lower shaft bearing.
Place the operative part of the appliance for 5 to 10 minutes in a
jug with hot water, then switch it on. In general the appliance will
then work again; if not, just try to free the shaft carefully with pliers.
Storage
Tripod
The bamix should always be placed ready to hand where you
work (preferably between the stove and the sink).
The more handily bamix is placed, the more often it gets
used.
33