By default the progressive cut mode is activated. The progressive cut favours a touch-sensitive cut with
more control. The pulse cut makes cutting quicker, but there is less control:
1.
Squeeze the trigger with the shears turned off, keep squeezing the trigger and press the power button.
2.
3.
The cutting mode has now been changed.
4.
Repeat this operation whenever you want to change the cutting mode again.
1.
Turn the shears on.
2.
Squeeze the trigger twice to activate the shears.
3.
Keep squeezing the trigger for 2 seconds until you hear the beep.
4.
The opening has now been changed.
5.
Repeat this operation whenever you want to change the opening.
1.
Turn the shears on and keep pressing the power button.
2.
3.
The system will be activated.
4.
Repeat this operation to disable it.
CAUTION:
The cut prevention safety system only works when the user touches the cutting head or comes
into contact with an electrical conductor. In the other cases, (3rd party who touches the shears, using
gloves, etc.) the cut prevention safety system does not work properly. Bellota cannot be held liable for any
faults when using this cut prevention safety system, which is not 100% reliable in all cases.
48
In case of any fault, please handle it according to the prompt code on the display screen.
Fault prompt on the display screen:
Meanings of Shears Alarms
The mainboard's
Alarm content
several times.
No fault
Anti-hand cutting protection
Current sensor error
MOS tube damage
Hall fault/blade breaking
Peak overcurrent/average current protection
Blocked opening/blocked rotor
Default phase
Undervoltage/overvoltage
MOS/chip over-temperature
PWM communication failure/ shears bit voltage
error
Shears bit type error
EEPROM error
Phase detection failure
Programming error
> historical pruning times
> maintenance pruning times
The number of batteries in the
shears bit and battery pack is different
The mainboard fails to communicate with the
battery pack.
The mainboard's
Display fault
Other
BUZ rings for
of the LED
Instructions
several times
0
0
E00
1
1
E01
2
6
E02
3
6
E03
4
3
E04
5
5
E05
6
3
E06
7
4
E07
8
1
E08
9
6
E09
10
2
E10
10
7
E10
11
6
E11
12
4
E12
13
6
E13
14
5
E14
15
5
E15
16
9
E16
17
10
E17