USE IN ENVIRONMENTS WITH PERMANENT PRESENCE OF PEOPLE
• The generators can be used in well-ventilated rooms and when the percentage of polluting substances in the air does
not exceed danger levels for health.
• A good ventilation is guaranteed when the room's volume (in m
kW) of all the machines used in that room and when an air circulation through doors, windows or permanent openings can
be guaranteed, the size of which (in m
in that room.Openings must be also distributed in height.
• The concentration of dangerous substances in the air is acceptable until it reaches maximum levels and the
percentage of oxygen in the air exceeds 17% in volume.
The apparatus should not be used for continuous heating of stables and farms.
MAINTENANCE
• Before starting any kind of maintenance and repair operations, always disconnect.
• Maintenance only concerns the burner outlet cleaning, the possible replacement of the calibrated nozzle and the
replacement of the flexible hose, in the event of extended use.
• Air outlet and nozzle are on the device upper part so being easily accessible by removing the control box by means
of its 4 screws.
• Maintenance procedures are quite simple and do not require technical expertise.
Check the distance of the electrode and the safety
thermostat. Intervene only if necessary.
PROBLEM
The motor does not start
The flame does not ignite
The flame extinguishes after
a few seconds of ignition
The flame has a white
luminous outline
The pilot light does not light
(AUTOMATIC models only).
The fan and burner do not
ignite
(AUTOMATIC models only)
) is at least 0,003 times the nominal calorific power (in kW) of all the machines used
2

TROUBLESHOOTING

CAUSE
1. Faulty power supply cable
2. Faulty fan
3. Faulty switch
1. Excessive distance between electrode and burner
2. There is no gas
3. Faulty gas valve
1. Excessive distance between the temperature
2. Gas button not held down long enough
3. Faulty safety chain
1. Air fault in the burner
2. Excess of gas in the burner
1. The nozzle in the pilot light device is clogged
2. The vent in the 50 mbar reducer is clogged
3. The ignition electrode is not sparking
4. Apparatus not properly ignited
The thermostat is either not plugged into the
socket on the generator or is not properly
plugged in
) is at least 30 times the nominal calorific power (in
3
1. Replace or repair
2. Replace or repair
3. Replace or repair
1. Adjust distance
2. Replace cylinder
3. Specialized work needed
1. Adjust distance sensor and theburner
2. Keep the button pressed down slightly longer (max 20
seconds)
3. Specialized work needed
1. Clean air inlet
2. Adjust pressure and/or replace nozzle
1. Remove the nozzle from the pilot device and clean
it with a jet of air.
2. Replace the 50mbar reducer located inside the base
3. Make sure the wire of the electrode is properly
connected
4. Make sure the ignition sequence is correct, follow
the instructions given in the manual
Make sure the thermostat is properly plugged into
the socket
3 - UK
Push button to restore
the safety valve.
REMEDY