Function confi guration.
First step: Confi guration of commands.
1.
Press the PRG button, the C led should light up.
2.
If you want the relay to activate with the F1 command,
the
C
led should fl ash slowly.
3.
In a residence terminal press the F1 button. The relay leds should remain off.
Second step: Confi guration of the command´s origin (residence terminals).
The F1 command, relative to the residence terminals sending them can be confi gured as:
a) All installed terminals (ALL).
b) Terminals from a list (maximum 100 terminals).
c) Terminals included within a defi ned range (consecutive).
a) Confi guration: All installed terminals (ALL).
1. Press the PRG button twice, the D led should light up.
2. Press the Min/All button. The relay leds should remain off.
b) Confi guration: Terminals in a list (maximum 100 terminals).
1. Press the PRG button twice, the D led should light up.
2. Press the Sec/Single button. The D led should fl ash quickly.
3. From a street panel, make a call to the telephone address we want to assign this function.
The Relay On led should light up if the telephone address is not on the list. The telephone
has been added to the list.
If you want to add more telephones, repeat this step.
To fi nish, press the PRG button.
Note:
- When the list is complete (100 terminals), the Relay On led fl ashes quickly.
Steps to DELETE the complete list
1.
Press the PRG button twice, the D led should light up.
2.
Simultaneously press the Sec/Single and Min/All buttons. All leds should be off. The list
has been deleted.
c) Confi guration: Terminals included within a defi ned range (consecutive).
1. Press the PRG button twice, the D led should light up.
2. Press the Sec/Single button. The D led should fl ash quickly.
3. Press the Min/All button. The D led should fl ash slowly.
4. From a street panel, make a call to the fi rst address in the range. Leds C and D should
blink slowly.
5. From a street panel, make a call to the last address in the range. The last address should
be greater than the fi rst one. All leds should be off.
Page 18
press the
SEC/Single button and