7.2/
Connect X1:
GB
7.3
S1
Impulse button
S2
Opening contact for hold circuit
1
Connect potential-free impulse button
2
Connect potential-free impulse button
3
12 V DC - Only if the lighting is on
(100 mA max.)
4
Hold circuit
5
GND
7.4
• Connect the drive system to the mains power supply.
7.5
Overview of the control unit
A
Seven segment display
B
MINUS button (e.g. to decrease parameters when
programming)
C
PLUS button (e.g. to increase parameters when
programming)
D
OK button (e.g. to save parameters)
Displays in operating mode
Display in standby and during door operation.
Drive system receives a command from the hand
transmitter.
Drive system receives a command from the OK button.
Drive system receives a command from the external input
unit.
Initial programming
Caution!
During the learning runs the drive system automatically learns the
required driving power and the soft run and checks the end
positions.The safety device is deactivated during these runs. The
learning run must therefore only be carried out if the operator
monitors the door while it is moving.
OK
OK
OK
Note:
The drive system carries out a reference run as far as the
mechanical stop in the CLOSE direction.
OK
OK
8
Drive system is in standby.
Open programming mode.
Select hand transmitter programming.
Start hand transmitter programming.
Programme hand transmitter to drive
system.
Select end position programming.
Endlagenprogrammierung starten.
Set the CLOSED door position.
Save the CLOSED door position.
Set the OPEN door position.
Save the OPEN door position.
Select learning runs.
Confirm learning runs.
Start learning runs.
End programming.
OK
Drive system is in standby.
Advice:
i
The two-channel hand transmitter is supplied with a synchronised
code (both buttons emit the same signal).
If required, the coding of the second channel can be changed.
Please refer to the hand transmitter instruction manual supplied
for details.
7.6
• Fix the cover cap to the motor unit.
8.
Operation
Open the door / close the door
The garage door operator can be operated with the hand transmitter, the
OK button or an external input unit (optional accessory).
The garage door operator has a one-button impulse contact control:
1st impulse (button pressed): door OPENS
2nd impulse (button pressed): door stops
3rd impulse (button pressed): door CLOSES
4th impulse (button pressed): door stops
5th impulse (button pressed): door OPENS
...
Caution!
The drive system automatically carries out runs at regular intervals
as far as the mechanical stop in the CLOSE direction to check
internal parameters.
Release mechanism
Release the door (fig. 8.1)
Lock the door (fig. 8.2)
9.
Malfunctions
Power interruption
Following a power interruption, at the first impulse the drive system
moves the door as far as it will go into the door CLOSED position in order
to find its reference.
Fault messages
In the event of a fault message the door control alternately displays E and
the relevant fault number.
Fault indicator Cause
The door control has recog-
nised a system fault.
The closed circuit is inter-
rupted, the motor unit is
stopped immediately.
Undervoltage,
the motor unit is stopped
immediately.
Overloading of drive
system, the motor unit is
stopped immediately.
Fault in impulse transmitter
or motor unit is blocked.
Solution
The control is blocked. The
drive system must be
checked by a qualified
specialist.
After remedying the fault,
the fault message also
expires.
Have the external power
supply checked.
Make sure the door can
move freely.
- Replace impulse transmitter.
- Make sure that the door
.
can move freely