Electrical installation
Power supply
Fuse protection
RCD
Pre-installation
>
Installing a permanent power supply line (Combi/Jet L
with temperature module lay second supply lines):
•
Pre-connect a separate fuse and
residual current operating device (RCD)
•
Pre-connect an all-pole separating main switch
outside the prescribed safety areas (0 - 2)
•
Allow the supply line to protrude by 3,000 mm
>
Laying the potential equalisation cable:
•
Allow the cable to protrude by 3,000 mm
18
connecting the whirltub (Diagram 18)
NotE! Avoiding any malfunctions!
•
Do not fasten the cables together with cable ties.
•
Do not install the supply line parallel to the control
cables.
I
Connect the supply line to the mains supply
socket.
Combi/Jet L with temperature module: connect
second supply line to the mains supply socket.
II
Connect the potential equalisation cable to the
whirltub.
50 Hz: 230 V~AC
60 Hz: 220 V~AC
I
= 16 A
N
I
≤ 30 mA
ΔN
0
6 0
1
0
I
L
N
PE
II
WH_M_Paiova_angeformte_Verkleidung_Monolith/11.10.1
6 0
0
2
3
* or the height of
the highest shower
head / water outlet
that is permanently
installed; depending
on which is higher
7