APPLICATIONS
Take the maximum consumption of the camera into consideration when installing the system because this
parameter will considerably affect the maximum distance which may be reached using the 24 AWG UTP
CAT5 cable.
Example:
The maximum distances which may be reached using a 12V power supply are shown in the table 2.
Maximum consumption of camera (mA)
Important note:
•
The use of Urmet Domus Ref.1092/800-801 power supplies with 13.2 V output is recommended.
•
The consumption of cameras without IR light is normally approximately 200-300mA.
•
The consumption of cameras with IR light is higher than 300-400mA
•
Always check the technical features of the cameras to be powered on the corresponding instruction
manual.
•
The distances may vary according to the wire quality also when the latter is made by the same
manufacturer as the devices.
•
Consider that the distances may decrease if the devices are used with DVR apparatuses.
TECHNICAL SPECIFICATIONS
Video input/output:............................................................................................................................Male BNC
UTP cable input/output: ...........................................................................................................Terminal board
Recommended wire type:.................................................................................24 AWG UTP CAT5 or higher
........................................................................... Impedance 100 Ω ± 20%, resistance DC loop 18 Ω/100 m
BNC impedance: .......................................................................................................................................75 Ω
UTP impedance:......................................................................................................................................100 Ω
Power connector:......................................... male jack 2.1mm user side - female jack 2.1mm source side
Working temperature range:............................................................................................................... -10-45°C
Storage temperature range: ............................................................................................................... -30-60°C
Humidity:................................................................................................................................................. 0-95%
Dimensions (W x H x D) : ................................................................................................... 22 x 20.5 x 43 mm
Weight (each): ........................................................................................................................................... 35gr
Important note:
Technical features may be subject to change without prior notice.
8
150
250
350
500
Table 2: distances with 24 AWG UTP CAT5 cable
Maximum reachable distance (m)
130
80
50
40
DS1092-016A