3
Mounting the wall bracket
3.2
Preparing for mounting
Figure 3
NOTE – Socket outlet with earthing contact:
Für den Netzanschluss ist eine ordnungsgemäß geerdete
Schutzkontakt-Steckdose im max. Abstand von 1,6 Meter zum
Wandlager notwendig
For the power supply a properly earthed socket outlet with earthing contact at a
max. distance of 1.6 m from the wall bracket is necessary.
The socket outlet with earthing contact must have at least 10 ampere protection.
We recommend that the wiring in your salon is protected with a residual current
circuitbreaker (RCCB) fitted by your electrician.
1. Check the wall for existing water pipes and power cables.
2. Remove the two plastic covers
3. For a height clearance of D > 2000 mm, mark the lower hole
finishedfloor according to the table in section 3.1.
4. Mark the upper hole
5. Drill two holes as directed by the fixture manufacturer and clean thoroughly
(uncleaned holes significantly reduce retention).
6. Insert fixture vertically and flush with the wall and allow any bonding agent
to set.
3.3
Mounting
Figure 4
1. Screw on wall bracket vertically, using the fixtures. Tighten the fixtures to the
tightening torque stated by the fixture manufacturer using a torque wrench.
2. Check that the wall bracket is securely in place.
3. Position the two plastic covers
place.
4. Remove cover
5. Pull out cable
Push remaining cable back into wall bracket.
6. Replace cover
-Figure 03
.
/
vertically using the enclosed drilling template
-Figure 04
/ and check that they are securely in
on the underside of the wall bracket
①
so that it reaches the socket outlet with earthing contact.
②
①
16
.
above the
GB
D