Troubleshooting - Diamatic 3140 DBP Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

The choice of professionals
Problem
The vacuum cleaner does not start
The vacuum cleaner does not vacuum
correctly
The vacuum cleaner suddenly stops
Dust leaks from the vacuum cleaner
Electrostatic current on the vacuum
cleaner
US
www.diamaticusa.com

Troubleshooting

Cause
Lack of power supply
Clogged filters
Clogged vacuum hose
Circuit breaker activation
Filters are broken
Inadequate filter
Non existent or inefficient grounding
Remedy
Check for power at the socket.
Check the condition of the socket and
the cable.
If necessary, ask for assistance to
be performed by a manufacturer's
technician.
Check the filter cleaning operation or
replace the filters.
Check the compressor functionality
(see the relative manual).
Make sure that the compressed air
nozzles are aligned with the cartridges.
Check the vacuum hose and clean it.
Check the circuit breaker adjustment.
Check the motor electrical input.
Empty the container.
If necessary, ask for assistance to
be performed by a manufacturer's
technician.
Replace them with others of identical
type.
Replace it with another of a suitable
category and check.
Check all ground connections. In
particular on the vacuum inlet fitting;
replace the hose with an antistatic
hose.
12/12
Tabla de contenido
loading

Este manual también es adecuado para:

3140 lpp

Tabla de contenido