Dynamic Fluid Measurement
Modbus Address Table – 16 Bits
ADDRESS
DESCRIPTION
3001
Version Number
3002
Reversed
3003
Reversed
3004
Prev. Day of Current or Last Month Data Request
( + ) Day for the Current Month
( - ) Day for the Previous Month
Error Checking –
Invalid Data -> 999
Valid Data -> 900 + Day
3005
Spare
3006
Last Two Hours Minutes Data Request (1-12)
3007
Product Used
3008-3011
Meter ID
3012-3017
Spare
3018
Flow Computer Unit Number
3019
Disable Alarms (1=Yes)
3020
Spare
3021
Last Month Summary Report Request
3022
Last Month Summary Report Pointer
3023
Applicaton Tag
3024
Enable Calibration Mode (1=Yes)
3025
Calibration – Set Time (1-9 Hours)
3026
Last Daily Report Request (1=Latest,64=Oldest)
Daily Data Area in Location 3431-3511
3027
Last Monthly Report Request(1=Latest,6=Oldest)
Set Last Monthly Report Request to 1
Monthly Data Area in Location 3431-3511
3028
Reserved
3029
Last Hourly Report Request(1=Latest,1536=Oldest) 0 Inferred
3030
Last Alarm Report Request (1=Latest,100=Oldest) 0 Inferred
3031
Last Audit Report Request (1=Latest,100=Oldest)
3032
Time Clock – Month
3033
Time Clock – Day
3034
Time Clock – Year (2 Digits)
3035
Time Clock – Hour
3036
Time Clock – Minute
3037
Time Clock – Second
3038-3081
Spare
3082-3121
Modbus Address Shift Data Area
Modbus
E-CHART Manual
16-bit
Address
www.dynamicflowcomputers.com
Modbus Data – 4-8
DECIMAL READ/WRITE
2 Inferred
Read
0 Inferred
Read/Write
0 Inferred
Read/Write
0 Inferred
Read
8 Chars
Read
0 Inferred
Read
0 Inferred
Read
0 Inferred
Read
0 Inferred
Read
0 Inferred
Read
0 Inferred
Read
0 Inferred
Read
0 Inferred
Read/Write
0 Inferred
Read/Write
Read/Write
Read/Write
0 Inferred
Read/Write
Read
Read
Read
Read
Read
Read
Read
Table
Ends