This manual contains important safety and operating instructions for chargers. Before using the charger, read this manual as well as any labels on the charger,
battery pack and tool.
1.
WARNING!
To reduce the risk of injury, charge only
MILWAUKEE 12, 14.4 and 18 Volt Power Plus Battery Packs in this
charger. Other types of batteries may explode, causing personal
injury or damage.
2.
AVOID DANGEROUS ENVIRONMENTS. Do not use charger in rain,
snow, damp or wet locations. Do not use battery pack or charger in the
presence of explosive atmospheres (gaseous fumes, dust or flammable
materials) because sparks may be generated when inserting or remov-
ing battery pack, possibly causing fire.
3.
CHARGE IN A WELL VENTILATED AREA. Do not block charger vents.
Keep them clear to allow proper ventilation. Do not allow smoking or
open flames near a charging battery pack. Vented gases may explode.
4.
MAINTAIN CHARGER CORD. When unplugging charger, pull plug
rather than cord to reduce the risk of damage to the electrical plug and
cord. Never carry charger by its cord. Keep cord from heat, oil and
sharp edges. Make sure cord will not be stepped on, tripped over or
subjected to damage or stress. Do not use charger with damaged cord
or plug. Have a damaged cord replaced immediately with identical
replacement parts (see "Maintenance").
5.
DO NOT USE CHARGER OR BATTERY PACK IF it has received a
sharp blow, been dropped or damaged in any way. Do not disassemble.
Incorrect reassembly may result in the risk of electric shock, fire or
exposure to battery fluids. If it is damaged, take it to a MILWAUKEE
service facility.
6.
CHARGER IS RATED FOR 120 VOLT AC ONLY. Charger must be
plugged into an appropriate receptacle.
7.
DO NOT USE AN EXTENSION CORD UNLESS IT IS ABSOLUTELY
NECESSARY. Using the wrong, damaged or improperly wired exten-
sion cord could result in the risk of fire and electrical shock. If an exten-
READ AND SAVE ALL INSTRUCTIONS FOR
2
1
4
5
6
Page 2
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
FUTURE REFERENCE.

FUNCTIONAL DESCRIPTION

3
7
sion cord must be used, plug the charger into a properly wired 16
gauge or larger extension cord that is in good electrical condition.
8.
DO NOT BURN, MUTILATE OR DISASSEMBLE BATTERY PACK.
The battery pack can explode in a fire. Mutilation may expose battery
fluids, causing burns.
9.
BATTERY FLUIDS CAUSE SERIOUS CHEMICAL BURNS. Never
allow contact with skin or eyes. If a damaged battery pack leaks bat-
tery fluids, use rubber or neoprene gloves to dispose of it. If skin is
exposed to battery fluids, wash with soap and water and rinse with
vinegar. Remove and dispose of contaminated clothing. If eyes are
affected, immediately flush with water for 15 minutes and seek medical
attention.
10. DO NOT SHORT CIRCUIT. A battery pack will short circuit if a metal
object makes a connection between the positive and negative contacts
on the battery pack. Do not place a battery pack near anything that
may cause a short circuit, such as coins or keys in your pocket. A short
circuited battery pack may cause fire and personal injury.
11. UNPLUG CHARGER when not in use.
12. TO REDUCE THE RISK OF ELECTRIC SHOCK, always unplug
charger before cleaning or maintenance. Use a Ground Fault Circuit
Interrupter (GFCI) to reduce shock hazards.
13. STORE YOUR BATTERY PACK AND CHARGER in a cool, dry place.
Do not store battery pack where temperatures may exceed 120°F (50°C)
such as in a vehicle or metal building during the summer. Charger will
charge the battery at the most rapid rate when the temperature is be-
tween 50°F (10°C) and 113°F (45°C). When the battery temperature is
outside that range, charging will take longer.
1.
Electrical Contacts
2.
Battery Pack Port
3.
Instruction label
4.
Green Control Light
Flashing light indicates:
Continuous light indicates:
5.
Red Control Light
Flashing light indicates:
Continuous light indicates:
6.
Vents
7.
Nameplate (on bottom of charger)
Charger is ready for operation
Battery pack is charged
Maintenance charging
Charging (Fast, if battery
temperature is between 50°F
(10°C) and 113°F (45°C).
Battery pack is too hot or too cold
Defective battery pack
Tabla de contenido