Accumulation activated .
Each coin inserted will have an increase in time equal to the value set in paragraph 4.2; once 24 hours is
exceeded, no further coins will be accepted until the remaining time returns to less than 24 hours.
Accumulation deactivated .
A single coin is accepted which will activate service. Any other coins inserted before the service has
ended will be rejected.
4.4.
Delay of service
The delay of service can be useful for allowing customers sufficient time to reach the service area or to prepare
themselves before using the service. In the case of showers, it can be useful for allowing sufficient time to reach the
shower or to undress before entering.
In Fig 8 identify the DIP-Switches with the word DELAY on them.
Set the DIP-Switches according to the tables below to obtain the delay time desired.
DIP-Switch
Time
[seconds]
4.5.
End of service notice
The DIP-SWITCH 4 (PRE in Fig 8) activates or deactivates the end of service notice as indicated below.
Notice activated.
The service is interrupted for 2 seconds when the remaining time is a 1 minute.
Notice deactivated.
The service remains activated for the entire programmed time.
4.6.
Start or stop the service manually
The LOAD ON/OFF button found on the electronic board (Fig 8) allows you to alternately start or stop the service. This
is useful for service testing and maintenance on part of the operator. It also allows to zero the loaded time, after the
introduction of coins for testing.
4.7.
Signal light
The red light on the front of the TA1w signals the following conditions:
A light briefly flashing every second indicates that there is power supply voltage present and that the service is
free and ready to be used.
5 fast flashes indicate that the coin has been accepted.
A slow flashing light indicates that the delay of service is being counted (chapter 4.4).
A constantly lit light indicates the service is in use.

1) DIP-Switches

for time of service (TIME)
2) DIP-Switches
for delay of service (DELAY)
3) LOAD ON/OFF button
Fig 8: Electronic board.
5197000015 TA1w manuale di uso e inst
DIP-Switch
[seconds]
0s
5s
Time
DIP-Switch
10s
20s
Pag. 8 / 32
Time
DIP-Switch
[seconds]
30s
40s
ENGLISH
Time
[seconds]
50s
60s