6.3 Dimensions
Linear units are produced individually to length in accordance with your specification.
The width and height of this linear unit is determined from the choice of size and design and can
be taken from the Linear Components catalogue.
6.3.1 Basic lengths/weights
PLM-II
Design
PLM-II 20x20
PLM-II 40x20
6.4 Loading data
In dynamic operation, this must be considered for the design:
6.4.1 PLM-II loading data*
Design
PLM-II 20x20
125 N
PLM-II 40x20
125 N
* referred to guidance slides (values static, guidance unit covering the whole area)
6.4.2 PLM-GII loading data*
Design
PLM-G II 20x20
-
PLM-G II 40x20
-
* referred to guidance slides (values static, guidance unit covering the whole area)
Basic length in mm
121
141
Fx max = m * a [m/s2]
Permitted forces
Fx
Fy
+Fz
160 N
90 N
200 N
110 N
Permitted forces
Fx
Fy
+Fz
160 N
90 N
200 N
110 N
6. Product information
Weight in kg
basic length
0.15
0.27
Permitted torques
-Fz
Mx
My
180 N
3 Nm
10 Nm
220 N
4 Nm
14 Nm
Permitted torques
-Fz
Mx
My
180 N
3 Nm
10 Nm
220 N
4 Nm
14 Nm
Weight in kg
per 100 mm travel
0.06
0.10
Mz
10 Nm
14 Nm
Mz
10 Nm
14 Nm
35