Appendix A: Error And Event Messages Of Tc 304 - Rohde TC304 Manual De Instrucciones

Ocultar thumbs Ver también para TC304:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
Heating up to final temperature:
The kiln is heated up to the final temperature at the preset speed; input in degree
Celsius per hour .
Press the
key to reach the input field „rmp2" (2. heating ramp).
Enter a value between 1 and 999°C / h, or select SKIP (full load heating) by
using the
or
Temperature for final temperature:
The kiln is heated at the speed set above until it reaches the final temperature; input
in degree Celsius .
Press the key , to reach the input field „tmp2" (final temperature).
Enter a value between 20 and 1320°C by using the
Dwell time at final temperature:
The kiln maintains the final temperature for the preset time . The dwell time ensures that
the goods are heated thoroughly and evenly .
Press the
key to reach the input field „t2" (dwell time at final temperature).
Enter a value between 0.00 and 9.59 (hours.minutes) by using the
Cooling down / End of program:
After the dwell time has timed out the kiln will cool down; this can either be carried
out ontrolled (e .g . 200° C/h) or uncontrolled (=SKIP) . At 150°C the controller will end
the temperature contol and display „End" in the display, which indicates the end of
the firing process .
Press the
key in order to reach the input field „rmp3" (cooling down time
or end of program).
Enter a value between 1 and 999°C/h by using the
(uncontrolled cooling down).
Storing of programs:
The TC 304 automatically stores all changeable values of the firing curve .