INSTRUCTION MANUAL
SPECIFICATIONS
Model
Rated Power (RMS)
Power Taps 100 V
Power Taps 70 V
Impedance
Sensitivity SPL (1 W / 1 m)
Sound Pressure SPL (12 W / 1 m)
Freq. Range
Dispersion 1 kHz / 4 kHz
Dimension (mm)
Weight
Finish
Colour
Mounting
Power selection
Protection
Remarks
INSTALLATION GUIDE
Bracked mounted
AEI-12T Version 1.2
Wall or ceiling mounted
1/1
WARNING:
⋅ Installation by qualified personnel only.
⋅ Speakers must be wired in parallel and connected to
the correct line terminals of amplifier.
⋅ Ensure that all speakers have the same polarity with
respect to each other.
⋅ Do not select another tapings if the speaker is in use.
⋅
No naked flame sources, such as lighted candles,
should be placed on the apparatus
AEI-12T
12 W
12 W, 6 W, 3 W y 1'5 W & 8 Ω
6 W, 3 W, 1'5 W, 0'75 W & 8 Ω
833 Ω, 1k67 Ω, 3k33 Ω, 6k67 Ω & 8 Ω
98 dB SPL a 1 W, 1 m & 1 kHz
109 dB SPL a 12 W, 1m & 1 kHz
570 ~ 4.800 Hz
185º / 45º
Ø 143 x 110 (depth)
1 kg
High impact ABS with UV stable
Grey (RAL 7035)
U type bracket or screws
By cables
IP 67 ( IEC 529)
Stands for marine environments
Impedance
70 V
833 Ω
6 W
1k67 Ω
3 W
3k33 Ω
1,5 W
6k67 Ω
0,75 W
-
Common Common
8 Ω
-
HORN SPEAKER
AEI-12T
.
100 V
Cable
12 W
White
6 W
Blue
3 W
Yellow
1,5 W
Green
Brown
-
Red