Cleaning And Maintenance; Technical Data - HAEGER Versatile FH-200.007A Instrucciones De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

English
Summer service (ventilation only): turn the knob to setting
Heating at reduced power: turn the knob (3) to setting I (1000W).
Heating at full power: turn the (3) to setting II (2000W).
Switching off: turn the knob (3) to setting 0.
REGULATING THE THERMOSTAT
When the room has reached the required temperature turn the thermostat
knob in an anti-clockwise direction up to the point where the appliance
switches off and not beyond. The temperature fixed in this way will be
automatically regulated and kept at a constant level by the thermostat.

Cleaning and Maintenance

Before cleaning always remove the plug from the electrical socket.
Clean the air inlet / outlet grilles frequently.
Never use abrasive powders or solvents.

Technical Data

Model: ................................... FH-200.007A
Power supply: ........................ 220-240V~, 50/60Hz
Power consumption: ............ 2000W
Protection class: ................... ΙI
Model identifier(s): FH-200.007A
Item
Heat output
Nominal heat output
Minimum heat output
(indicative)
Maximum continuous heat
output
Auxiliary electricity consumption
At nominal heat output
At minimum heat output
4
Symbol
Value
Unit
P
1,847
kW
nom
P
0
kW
min
P
1,847
kW
max,c
el
N.A.
kW
max
el
N.A.
kW
min
Item
Type of heat input, for electric storage local
space heaters only (select one)
manual heat charge control, with
integrated thermostat
manual heat charge control with
room and/or outdoor temperature
feedback
electronic heat charge control with
room and/or outdoor temperature
feedback
fan assisted heat output
Type of heat output/room temperature
control (select one)
single stage heat output and no
Instructions for use
.
Unit
NA
NA
NA
NA
[no]
Tabla de contenido
loading

Tabla de contenido