Tennant 2300 Manual De Operador página 9

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TROUBLE SHOOTING
PROBLEM
Motor does not operate.
Machine circuit breaker trips
continuously.
Pad spins slowly or not at all.
SPECIFICATIONS
2300
MODEL
WIDTH
20.75 in / 530 mm
HEIGHT
49 in / 1,240 mm
LENGTH
29.75 in / 760mm
WEIGHT
68 lb / 31 kg
DRIVE MOTOR
120 V, 1.5 hp, 15 A, 60 H
PAD/BRUSH SPEED
1,200 rpm
POWER CORD
75 ft / 23 m Gauge 3 X 1.5 mm
LENGTH
PAD DIAMETER
20 in / 510 mm
DECIBEL RATING AT
70 dBA
OPERATOR'S EAR,
INDOORS ON TILE
FLOOR
Tennant 2300/2320/2340 (06- -06)
Home
CAUSE
Machine circuit breaker tripped.
(Spray buffing with the 2320 and 2340
models is not recommended).
Building circuit breaker tripped.
Faulty power cord.
Faulty wiring.
Faulty twist grip switch.
Faulty Rectifier.
Faulty Motor.
Soiled Pad.
Improper pad for application.
Defective circuit breaker.
Worn carbon brushes in motor.
Loose drive belt.
Broken drive belt.
2320
20.75 in / 530 mm
49 in / 1,240 mm
29.75 in / 760mm
68 lb / 31 kg
120 V, 1.5 hp, 15 A, 60 H
Z
1,600 rpm
75 ft / 23 m Gauge 3 X 1.5 mm
20 in / 510 mm
70 dBA
Find... Go To..
OPERATION
SOLUTION
Determine cause and reset breaker on
machine. Wait 15 seconds before
restarting machine.
Reset breaker and change to different
circuit.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Replace Pad.
Change to proper pad.
Contact Service Center.
Contact Service Center.
Tighten drive belt.
Replace drive belt.
2340
20.75 in / 530 mm
49 in / 1,240 mm
29.75 in / 760mm
68 lb / 31 kg
120 V, 1.5 hp, 17A , 60 H
Z
2,000 rpm
75 ft / 23 m Gauge 3 X 1.5 mm
20 in / 510 mm
70 dBA
Z
9
Tabla de contenido
loading

Este manual también es adecuado para:

232023406083266083259000449607879 ... Mostrar todo

Tabla de contenido