Safety Instructions - Fracarro KTX-RC Instrucciones De Uso

Transmisor y receptor óptico
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
Environmental conditions: These units are designed to be installed indoors. Do not
install it in places where corrosive vapors or critical environmental conditions are present
nor in dangerous areas.
Characteristics of the installation room: The installation of the unit must be performed
by a specialized technician and in a dry room with the following characteristics:
- the environment must not be classified as a high risk of fire
- there must not be high concentration of suspended particles
- the system must be placed in a private room protected from intruders
- the system must not be exposed to ultraviolet rays
- the site must be accessible to the maintenance personnel
- the room must be dry with a low humidity level
- the room must have sufficient space for cables and system ventilation
- do not install inside heating or air-conditioning systems
- do not install inside pipes or in areas for fire prevention (such as ways out, elevators,
tunnels, emergency exits) since they have to ensure defined safety standards
- the products must be accessible for controls and maintenance
- check that the room temperature does not exceed the limits.
Connection to the power: The connection to the power must be performed by trained
and skilful personnel according to local safety norms.
Safety and precautions: The KTX-RC optical transmitter includes a laser module and,
therefore, it is classified and labeled as a 3A class equipment according to the EN60825-1
regulation.
During the installation, follow the following instructions:
- never look inside the optical connector output when it is On (the wavelength of the laser
is not visible by the eye; therefore, long-term damage is not immediately felt).
- when working with optical connectors, always control when the laser is off.
Grounding of the antenna: the DIN bar, where the unit will be installed, must be collected
to the ground electrode of the antenna installation according to the EN50083-1 norm,
paragraph 10. We recommend following the provisions of the EN 50083-1 norm and not
to connect the DIN bar to the protection grounding of the power network.

SAFETY INSTRUCTIONS

Warning labels (KTX-RC)
Danger symbols (according to EN 60825-1) for laser
equipment.
WARNING! Laser radiation. Do not look inside the
beam or directly at it with optical instruments.
Laser product of 3A CLASS.
7
Tabla de contenido
loading

Este manual también es adecuado para:

Krx-rc

Tabla de contenido