Beper VE.501 Manual De Instrucciones página 11

Ventilador con nebulizador
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
Mist Fan Use instructions
PRODUCT DESCRIPTION Fig.A
1. Nebulizing ring
2. Top tube
3. Front grid
4. Grid closure hooks
5. Blade mounting ring
6. Blade
7. Rear grid fixing ring
8. Rear grid
9. Motor unit
10. Control panel
11. Motor fixing screws
ASSEMBLING THE FAN Fig.B
1 Insert the two carrying tubes into the plastic base, insert the perforated plate under the base as shown in the
picture.
2 Place the weight of the base so that the two holes combine with the perforated plate. Secure all with the two
screws complete of rings.
3-4 Place the nebulizer base in its housing.
5 Loosen the screws located behind the control panel and insert the motor unit on the two carrying tubes. Secure
the motor unit by screwing the two previously loose screws.
6 Place the rear grid in its housing and secure it by turning it clockwise with the appropriate ring.
7 Insert the blade and secure it by turning it counterclockwise using the appropriate ring.
8 Place the front grid and close it with the appropriate hooks and screw.
9 Connect the top tube by inserting it into the appropriate housing placed ahead of the front grille.
10 Take the water tank, overflow it and unscrew the cap placed on the bottom.
11 Fill in the tank with water and close the cap.
12 Place the tank on the nebulizer base, making sure that the cap is aligned correctly in it housing.
13 Place the perforated lid on the tank. Insert the lower tube into the hole of the lid.
Important: Fix all the components firmly to the base in order to ensure a good fan stability, otherwise the fan
would oscillate dangerously
OPERATION:
When the assembly is complete, plug in the appliance.
A red LED lights up.
ON / SPEED button is used to activate the fan (the red LED NORMAL lights up) and to choose the desired speed
(the red LED LOW lights up automatically); pressing the ON / SPEED button repeatedly to select the desired
ventilation speed (depending on the selection, the red LED LOW MIDDLE or HIGH lights up).
SWING button to activate the horizontal oscillation of the fan head (the red LED SWING lights up). The oscilla-
tion allows an equal air distribution in the room. Press the button again to turn off the swing (the red LED SWING
switch off).
MIST button (misting) is used to activate water nebulization (the blue LED MIST light up). Put the button placed
on the base of the nebulizer on the selection I (a red LED lights up above the nebulizer knob). Select the water
mist intensity with the knob to minimum to maximum following the drawing.
IMPORTANT !!: The water tank must be filled in before proceeding with this function.
MODE button is used to select different ventilation modes.
NORMAL: The blade rotates continuously.
NATURE: The blade has an alternating or wavy motion (alternates moments when the blade rotates with a cer-
tain intensity, moments where it slows down to almost stop, then resumes).
SLEEP: The blade rotates with a slower speed than the previous ones.
The red LED lights up in accordance of the selected mode.
Press the TIMER button (when the fan is working) to set the sleep timer (the red LEDS will light up in accordance
of the set time).
The adjustable time is 7.5 hours maximum; pressing the button TIMER the time will be set with a half-hour
progression. Red LEDS light up in accordance of the selected time. Press the OFF button to end the ventilation.
12. Carrying tubes
13. Bottom tube
14. Perforated lid
15. Tank
16. Tank closure cap
17. Nebulizer base
18. Nebulizing switch
19. Nebulizer adjustment knob
20. Plastic base
21. Perforated plate
22. Screws with ring for base
23. Weight for the base
11
EN
Tabla de contenido
loading