national regulations in force (BS, UNi, UNe, etc....).
the hose shall be 0.50 m long. it shall be replaced if
it appears to be damaged or cracked. do not pull or
twist the hose. Keep it away from parts that are likely
to get heated.
- Check tightness in compliance with indications of
paragraph d-2.
D - CONNECTING THE GAS BOTTLE
if an empty bottle is in place, read paragraph
F-"removing or replacing gas bottle".
to install or remove a gas bottle, always operate
in a well-ventilated place and never in presence of
a flame, spark or heat source (cigarette, electric
appliance, etc.).
- open appliance rear plate (fig. 1 item 3).
Note: if the appliance is new, remove the plastic cable
tie (Figure 1 number 4), lift and remove rear plate (3).
D - 1 - Installing gas bottle:
- Position the gas bottle on the floor behind the appliance.
- Check whether bottle cock and/or pressure reducing
valve handle is in "closed" position.
- Screw in or engage pressure reducing valve to gas
bottle or gas bottle cock (fig. 3 item B).
- install gas bottle through appliance rear so that the
hose does not touch appliance metal panels and is
not excessively bent or pinched.
- Check that the hose runs normally and is neither bent
nor pulled.
- install appliance rear plate (fig. 4 item a).
D - 2 - Tightness:
In case of leak, appliance gas supply must be
shut down using gas bottle cock and/or pressure
reducing valve handle.
Do not carry out leak tests with a flame, use a gas
leak detecting liquid.
- apply gas leak detecting liquid to bottle/pressure
reducing valve/hose/appliance unions.
- open the gas inlet (bottle cock and/or pressure
reducing valve handle) (fig. 4).
- if bubbles appear, this means that there are gas
leaks.
- to remove the leak, tighten hose nuts and/or hose
clamps if any. if a part is defective, have it replaced.
the appliance should not be returned to service until
the leak is removed.
- Close gas bottle cock.
Important:
In case of gas leak or odour, immediately close
bottle cock and/or pressure reducing valve handle.
Enhance room ventilation by opening the windows.
Ask a specialised technician to check the appliance
and proper bottle connection.
a leak test should be carried out at least once a year
and whenever the gas bottle is changed.
E - UTILISATION

OPERATING PRECAUTIONS

DO NOT install the appliance next to a wall,
curtains or a sofa or armchair.
DO NOT cover the appliance with clothes or other
objects.
DO NOT move the appliance when in operation.
The appliance must ALWAYS be directed to the
centre of the room.
The appliance must be put in a dry place.
This appliance protecting grid is designed to
prevent fire hazards or burns and no part shall be
permanently removed.
THE GRID DOES NOT TOTALLY PROTECT YOUNG
CHILDREN OR THE DISABLED.
E - 1 - Igniting the appliance
Note: Gas opening and closing controls are located on
gas bottle and/or on pressure reducing valve.
ignition spark, gas inlet control and temperature or
power controls are actuated from the control panel
located in the appliance top right section (fig. 1 item 1)
and (fig. 5 items a, B and C).
1- open bottle cock and/or pressure reducing valve
handle and carry out a leak test.
2-a-CR 5000 Version and CR 5000 Turbo Versions
electrically connect the Cr 5000 turbo Version.
Caution: the appliance was designed to be supplied
with a 230 V 50 Hz voltage. Your installation must be
equipped with a grounding connection compliant
with electrical systems specifications in force.
- do not place the heater just below an electric socket.
- do not use the heater near a bath, shower or
swimming pool.
Set handle (a) to position (START) and press the
handle for 10 seconds to allow the gas to reach the
pilot burner (fig. 5).
2-b-CR 5000 Thermo Version
Set handle (C) to the maximum position (IIII) and
press control button (a) for 10 seconds to allow the
gas to reach the pilot burner (fig. 5).
3- Fully press several times the LH button marked with
a stylised lightning (
flame, while holding handle (a) or control button (a)
depressed for 10 seconds. the thermocouple is
activated and the safety valve does not cut off gas
feed.
release button a or handle a.
4- Check whether the appliance did light up. if not,
repeat the procedure from step 2).
5- the appliance must be held in maximum position for
about 10 minutes in order to fully activate the catalytic
panel.
Note: Some air may be trapped in the gas line. this
will prevent the appliance from lighting up during the
first attempt. in this case, it is necessary to repeat the
ignition procedure several times until the safety pilot
burner lights up.
during appliance operation, the safety pilot burner
must remain permanently lit in order to ensure correct
operation of the atmosphere analyser.
during the first setting to service, operate the appliance
at maximum power for at least 15 minutes in order
to eliminate the typical new appliance smell due to
the presence of protecting substances applied to the
component parts.
Ventilate the room during this operation.