Replacement Parts; Disposal Instructions - Grohe MintaTouch 31 358 Manual De Instrucciones

Ocultar thumbs Ver también para MintaTouch 31 358:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
Maintenance
Inspect and clean all components and replace if necessary.
Shut off hot and cold water supply.
Disconnect all plug-in connectors, see fold-out page II,
Fig. [11].
I. Cartridge, see fold-out page IV, Fig. [21].
Assemble in reverse order. When installing the cartridge,
ensure that the seals are correctly seated. Tighten the screws
evenly and alternately.
II.Pull-out spray with non-return valve, see fold-out page IV,
Fig. [22].
Assemble in reverse order.
III. Battery, see fold-out page IV, Fig. [23].
The battery must be replaced 10 years after commissioning of
the fitting at the latest.
Batteries which are almost discharged are indicated by 3 water
pulses. If the battery is discharged the indicator lamp in the
sensor system also flashes.
Assemble in reverse order.
Insert battery with correct polarity!
IV. Control, see fold-out page IV, Fig. [24].
Assemble in reverse order.
V. Solenoid valve with non-return valve and filter, see fold-
out page IV, Fig. [25].
Assemble in reverse order.
Fault
Cause
Water not flowing
• Water supply interrupted
Water flow does not
• Water supply interrupted
start after touch
• Filter in solenoid valve blocked
• Plug-in connector of solenoid valve without
contact
• Solenoid valve defective
• No voltage
- Battery discharged
- Plug-in connector without contact
• cleaning mode activated
• Sensity of sensor system incorrectly
adjustetd
Water flowing
• Solenoid valve defective
continuously
• Sensity of sensor system incorrectly
adjustetd
Undesired water
• Sensity of sensor system incorrectly
flow
adjustetd
• Trip by moisture
Undesired opening
• Using a metal sink
or closing of fitting
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
• Shut-off valves, service valves not fully open
• Water supply restricted

Replacement parts

See fold-out page I (* = special accessories).
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.

Disposal instructions

This category of device does not belong in the
domestic waste, but must be disposed of
separately in accordance with the relevant local
national regulations.
Dispose of batteries in accordance with national
regulations.
Remedy
- Open shut-off valves, service valves
- Open shut-off valves, service valves
- Clean filter
- Attach plug-in connector
- Replace solenoid valve
- Replace battery
- Check plug-in connectors
- Wait 2 minutes
- Adjust sensitivy
- Replace solenoid valve
- Adjust sensitivy
- Adjust sensitivy
- Discard any damp cloth on the lever, reduce
humidity and ambient temperature
- Connect sink to ciontrol by using the supplied
cable
- Clean or replace mousseur
- Clean filter
- Fully open shut-off valves, service valves
- Check supply lines, open shut-off valves,
service valves
4
Tabla de contenido
loading

Este manual también es adecuado para:

Mintatouch 31 360

Tabla de contenido