Parts List; Troubleshooting - Global 761012 Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

SET UP & OPERATION
1. Place the dispenser upright.
2. Position the unit at least 4 inches away from the wall on all
sides(rear, left and right).
3. Clean outside of the water bottle cap and neck with a cloth and
warm soapy water, then rinse.
4. Tear the label from the water bottle cap then insert the bottle
vertically into the bottle supporter.
5. Plug the cord into a ground fault circuit interrupter (GFCI)
outlet only.
Note: Once the bottle is empty, turn off the switches and
replace with new bottle.
ACTIVATE HOT OR COLD WATER
1. To activate heating, turn on the red switch. After activation, the
hot water will be ready in 15-20 min.
2. To activate cooling, turn on the green switch. After activation,
the maximum cold temperature water will be achieved in
approximately 1 hour.
NOTICE:
1. The unit will not dispense Hot or Cold water until the switches
are activated. Room temperature water will be dispensed if both
switches are off.
2. If the bottle is empty turn off both switches.
DISPENSING COLD WATER
1. Place cup, bottle, or pitcher below cold water tap.
2. Raise the lever until the desired water level
is achieved.
DISPENSING HOT WATER
Note: Hot water tap is equipped with child safety lock.
1. Place cup, bottle, or pitcher below hot water tap.
2. Press red child safety lock on top of the lever,
then raise the lever until the desired water level is
achieved.
MAINTENANCE
Note: Before performing maintenance,
unplug the unit.
Cleaning should be done every 3 months.
General Cleaning
1. Use a vacuum to clean the condenser. Use a clean wet cloth to
remove dirt from the unit, taps and especially the condenser.
2. Empty and clean drip tray as needed.
Water tank cleaning
Items needed: 1 tablespoon of regular bleach, 1 gallon of hot water
and a large bucket.
1. Unplug the dispenser and move away from
the wall.
2. Mix bleach and hot water together.
3. Remove the water bottle, bottle supporter
and baffle. Bottle supporter and baffle can be
cleaned with dish washing soap and tap water.
4. Place a bucket under the taps. Drain the remaining
water in the tank by opening the hot and cold water taps.
5. Slowly pour hot water and bleach solution into the tank and wait
ten minutes.
6. Dispense the solution from the hot water tap and then the cold
water tap.
7. Place a bucket under the drain plug. Open the
drain plug and remove the silicon cap in the
back to empty the hot reservoir.
8. Reinstall the drain plug and silicon plug.
9. Repeat steps 5-8 a minimum of 2 or 3 times
using regular tap water to remove the
remaining bleach solution.
10. Reinstall baffle, bottle supporter and
water bottle.
Top Mount Bottle Cooler
Child Safety
Lock
Baffle
Drain Plug
2

PARTS LIST

1
2
3
4
5
6
7
FRONT
NO.
PART NAME
1
Bottle Supporter
2
Power Indicator Light
3
Heating Indicator Light
4
Cooling Indicator Light
5
Cold Water Tap
6
Hot Water Tap
Note: This machine is suitable for 3 or 5 U.S. gallon
(11.4 or 19L) bottles. Do not use bottles filled with distilled water.

TROUBLESHOOTING

Problem
Water is not coming out
of the taps.
Cold water is not cold.
Hot water is not hot.
Dispenser is noisy.
User's Manual
REAR
NO.
PART NAME
7
Drip Tray
8
Cold Switch
9
Hot Switch
10 Power Cord
11 Silicone Drain Plug
12 Condenser
Solution
Make sure the bottle is not
empty. If it is, replace it.
It takes up to one hour after
setup to dispense cold water.
Make sure the unit is plugged
in and the cold water switch
is on.
Make sure the back of the unit
is at least 4 inches away from
the wall.
Clean the condenser.
It takes 15-20 minutes after
setup to dispense hot water.
Make sure the unit is plugged in
and the hot water switch is on.
Place the dispenser on a level,
flat surface.
8
9
10
11
12
Tabla de contenido

Solución de problemas

loading

Tabla de contenido