6. Technical data

Model No.
Temperature ranges
Measurement units
Sensor
Supply voltage
Power consumption
Process connections
• Fixed thread
• Compression fitting
Werkstoffe
• Process connection
• Housing
Stem and
working pressure
Outputs
30
Betriebsanleitung / Operating manual / Instructions de service / Instrucciones de uso
S5400 – PT100 with two switching outputs
S5410 – PT100 with one switching output and one analogue output
-50 to +125°C (Standard)
-50 to +200°C
0 to +400°C
0 to +600°C
-200 to +600°C
°C or F (selectable)
PT100 class B or PT100 class A
12...30V DC, overload and reverse polarity protection
ripple <10%
≤ 50mA, without load current
G1/2 A, G1/4 A, G3/8 A, G3/4 A, 1/2NPT, 1/4NPT
G1/2 A, G3/8 A, G1/4 A, 1/2NPT
Other connections on request
Stainless steel 1.4571 (316Ti); other materials or coatings on request
Stainless steel, display cover plastic
• from stem length (EL) 50mm: ø6 x 0,75mm (up to 40bar)
• from EL 50mm: ø8 x 1,75mm (up to 100bar)
• from EL 50mm: Special parts made of solid material (up to 500bar)
Fast response time version (up to 12bar)
• EL 25mm: ø3 x 0,25mm without taper
• EL up to 100mm: ø6 x 0,25mm with taper to ø3 x 0,25mm
• from EL 100mm: ø8 x 1,75mm with taper to ø6 x 0,25mm with taper
to ø3 x 0,25mm
2 switching outputs PNP or
1 switching output PNP and analogue output 4...20mA