6. ADJUST THE "LOW" SETTING SURFACE
BURNER VALVE
SCREW IN STEM
1. Turn control to LITE until burner ignites.
2. Quickly turn knob down to LOWEST POSITION.
3. If burner goes out, readjust valve as follows:
Remove the surface burner control knob, insert a thin-
bladed screw driver into the hollow valve stem and engage
the slotted screw inside. Flame size can be increased or
decreased with the turn of the screw. Adjust flame until you
can quickly turn knob from LITE to LOWEST POSITION with-
out extinguishing the flame. Flame should be as small as
possible without going out.
7. MAKE SURE RANGE IS LEVEL
Level the range by placing a level horizontally on an oven
rack. Check diagonally from front to back, then level the
range by either adjusting the leveling legs or by placing
shims under the corners of the range as needed.
8. WHEN INSTALLATION IS COMPLETE, CONNECT THE
POWER CORD AND SET THE TIME OF DAY ON THE ELEC-
TRONIC OVEN CONTROL AS EXPLAINED IN THE
OWNER'S GUIDE.
9. VERIFY THE OPERATION OF THE ELECTRONIC CON-
TROL FUNCTIONS AS PER INSTRUCTIONS GIVEN IN THE
OWNER'S GUIDE.
10. MAKE SURE THE AIR FLOW FROM THE OVEN VENT
AND THE AIR FLOW TO THE BOTTOM FRONT OF RANGE
IS UNOBSTRUCTED.
HOW TO CONVERT THE RANGE FOR
USE WITH LP GAS
1. CONVERT THE PRESSURE REGULATOR
Do not remove the Pressure Regulator.
L.P.
Remove cap-screw and snap out the nylon gas indicator by
pushing it sideways. Turn the nylon gas indicator for type
gas (Natural or LP) and snap it back in the cap-screw. Put
cap-screw back on gas regulator.
2. CONVERT SURFACE BURNER VALVES
FOR LP GAS
TOP BURNER ADJUSTMENT
1. Lift cooktop to gain access to the surface burner spuds.
2. With 1/2" wrench, turn spud down or clockwise until
snug (approximately 2-1/2 turns). This restricts the flow of
gas through spud to that allowed only by the hollow LP me-
tering pin. Do not overtighten.
NATURAL GAS
INCREASE GAS
INCREASE FLAME SIZE
(PRE-SET AT FACTORY
FOR NATURAL GAS)
5
CAP SCREW
AIR SHUTTER
HOOD
NAT.
L.P.
PIN
PIN
SPUD
L.P. GAS
DECREASES GAS
DECREASES FLAME SIZE
NAT.