Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26

Wiring diagram

CP W
CP W
1/4
1/4
0
Made in Germany
Made in Germany
2 pol.
2 pol.
WH 1/1
BN 3/4
1
GN 1/2
YE 1/4
GY
0
BU = blue
WH = white
PK = pink
BN = brown
GN = green
YE = yellow
GY = grey
Supply battery (battery II)
The fuse must be attached close to the positive terminal
of the battery.
Waste water tank
Fresh water tank
8
1/1
1/1
3/4
3/4
1/2
1/2
Tank
Tank
I
II II
5 pol.
5 pol.
5 pol.
5 pol.
5
5
2
3
Installation of the filling level sensors
Waste water tank
The positions of the boreholes apply for symmetrical
tanks. The volume of non-symmetrical tanks needs to be
determined.
Establish the height of the
tank (external dimensions).
Establish and mark the posi-
tion of the 5 boreholes for
the sensors (1/4 H).
Drill 5 holes with a diameter
of 9.5 – 10 mm into the
waste water tank.
Smooth down the edges of
the boreholes.
Coat the screws with seal-
ing compound or an elastic
adhesive.
Assemble the measuring
sensors (1 wire of the 5-wire
line per measuring sensor).
Tighten the screws by hand.
Place each measuring sen-
sor into a borehole and
tighten with a screwdriver.
The edge of the rubber
seal is pressed against
the tank wall. The rubber
bulges inside thereby sealing
the borehole.
Tabla de contenido
loading

Tabla de contenido