4. Installation
The SwitchPanel must be installed in a location easily accessible to the driver
and must be secured by the two screws on the back.
4.1 Power Supply
Since the SwitchPanel draws 50mA of current when at idle, it's possible to
use the same power supply as the FuelTech ECU's.
Electric diagram
A - SwitchPanel;
B - DEUTSCH Connector;
C - CAN Network FT2.0 - To connect on ECU
(Power FT line);
D - CAN Network expansion FTCAN2.0 - to
connect others equipments FTCAN;
E -
CAN Terminator;
ATTENTION:
If there is a connection error in the CAN network, the currently active
functions will not be affected.
1 - Red Wire - Switch 12V;
2 - Black Wire - Ground;
3 - Yellow Wire - CAN LOW;
4 - White Wire - CAN HI;
NOTE:
The use of the Terminator (E) is
mandatory at the end of the CAN
Network to reduce the possibility of
noise in the network.
A
The electrical wiring is the same for
all SwitchPanels.
B
2
1
4
3
3
SwitchPanel
1
2
D
E
C
4
EN
7