Mechanical Installation; Location - Watts MQ 3-45 Instrucciones De Instalación Y Funcionamiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

8. Mechanical installation

8.1 Location

The pump is suitable for indoor and outdoor
installation. It is resistant to sunlight.
NOTICE
For outdoor installation, the pump
must be fitted with a protective cover
(accessory). See section 8.5 Protective
cover and 14. Accessories.
CAUTION
!
Should the unlikely event of an internal
leakage occur, pumped liquid will be
drained out from the base and/or end
cover instead of damaging the pump.
To prevent potential damage, select an
installation location that would not be
adversely affected by water.
The pump must be installed horizontally.
The maximum permissible inclination angle is ± 18 °.
See fig. 2.
Max. ± 18 °
Fig. 2
Horizontal installation of MQ
8
To prevent movement and vibrations, the pump and
base plate can be secured to a solid foundation by
means of the bolt holes in the base plate.
For pipework connection, see section 8.4 Pipework.
The bolt holes are covered by a thin plastic layer that
must be knocked out before use. See fig. 3.
Fig. 3
Knocking out the plastic layer in bolt
hole
19.0 cm
Fig. 4
Base plate
Tabla de contenido
loading

Tabla de contenido