tefen MixRite Manual Del Usuario página 7

Bomba de dosificación proporcional
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

In models 2510, 12510 there is no U-
latch and the adjustment is done by
turning the adjustment sleeve to the
desired %.
In models 2500, 2501, 2506, 12500,
12501, 12506 there is no possibility to
adjust the dosing percentage, it is
predeterment by the injector model (see
page 3).
DO NOT REMOVE THE LOWER U-LATCH !!!
(For maintenance purpose only)
Rinsing and Cleaning the unit
After pumping
• Rinse the unit by pumping clean water from the additives
container.
• Wash the external surface of the unit with clean water.
Warning: During pumping, ensure that the additive
container is not completely empty.
Air-release Valve
In models: 2500, 2501, 2502, 2504, 2506, 2510, 2512, 2514,
2512IN, 2514IN.
After initial operation of the MixRite, apply pressure to the cap (the
air release valve) for several seconds to open valve that allows
trapped air to escape. This air release is accompanied by a slight
loss of water. Release the pressure on the cap to close the valve.
Press to release air
7
To decrease
Air is released with a
small amount of
water
U-latch
To increase
Tabla de contenido