Electrical Connection; Electrical Connection For Badu ® Jet Primavera - Speck BADU Jet primavera Manual De Uso

Ocultar thumbs Ver también para BADU Jet primavera:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 218
5 Installation
5.4

Electrical connection

WARNING! Risk of electric shock due to incorrect connections!
WARNING! Risk of electric shock due to voltage on the housing.
5.4.1
Electrical connection for BADU
Connection by customer:
Further information is provided in the connection diagram. These parts
are not included in the scope of delivery and have to be provided by the
customer at the installation site.
76 EN
VG 766.2320.050
Observe VDE and utility company regulations.
Install swimming pools and their protection according to
DIN VDE 0100-702.
Install a switch with at least 3 mm contact opening per pole to
interrupt the power supply.
A motor overload switch which is set correctly must be installed. In
doing so, observe the values on the motor name plate.
Protect power supply with a ground fault circuit interrupter, nominal
residual current IΔ
N
Only use suitable connection types according to regional
regulations.
Adjust minimum diameter of the pipes to the motor output and pipe
length.
If hazardous situations can occur, provide emergency-off switch
according to DIN EN 809. The builder/operator must make a
decision according to this standard.
The circuit is wired ready for connection. The connections are
carried out in accordance with the wiring diagram.
Connect the pneumatic hoses of the pneumatic buttons with the
control box.
Fusing 1-phase 230 V/3-phase 400 V safety fuse 20 A/16 A slow or
20 A/16 A circuit breaker.
All-pole switch with 0 and 1 identification.
A connection has to be provided for equipotential bonding, that is
connected with the earthing strap
≤ 30 mA.
®