6.4.1
Suggestion for winter conditions
For outdoor counter swim units that could be subjected to frost
during the winter.
Please observe the point "Decommissioning" on page 46.
1.
Remove the pump during periods of frost and store it in a dry
room.
2.
Leave the shut-off valves half open so that the housing and
lines can drain.
3.
Support the suction and pressure lines to relieve them. See
"Fig. 27".
4.
Water caused by rain can drain through the half-opened
shut-off valves to the waste duct.
Fig. 27
6.4.2
Assembling the dummy/winter plate
The following steps are necessary in order to assemble the
dummy plate:
1.
Observe the point "Disassembly" on page 43
2.
Attach the dummy plate (30) under the support ring (28) and
fasten it to the main housing (1) using four tapping screws
(103). See "Fig. 12" and "Fig. 13" on page 27.
The following steps are necessary in order to assemble the winter
plate (optionally available):
1.
Observe the point "Disassembly" on page 43 The nozzle
housing (102.1) must not necessarily be disassembled.
2.
Assemble according to the drawing attached to the packing
list. See point 1.3 on page 7
01|2018
Commissioning/Decommissioning
Support
WG23.140.054-2-P
EN 47