Taking the microscope into use

Utilisation with table stand
In the variant with a table stand the appliance is largely pre-assembled.
Move the microscope head a few centimetres upwards with the gear
wheel t.
Loosen the setscrew for the microscope head
head so that the eyepieces are directed towards you. Then tighten them
back up.
Place the two eyepiece cups
Unscrew the protective cap of the lens barrel
Look through the two eyepieces
eye spacing by turning the eyepiece bearer o either inwards or outwards.
For the individual optimal contrast select either the black or the white side
of the object bearer disc h.
To secure the disc, turn the setscrew
Place the object that is to be examined by microscope on the object bearer
disc.
With largish objects that are to be observed or processed, the spacing-
adjustment using the lateral gear wheels may not be sufficient. In this
case, you should first of all carry out a rough distance adjustment by
using the securing wheel (u, Model 33213). For this, orientate yourself
on the following table:
Select the required magnification (1x or 2x) by turning the lens barrel
through 90° for each.
(Model 33213)
i onto the eyepieces.
q. Adjust the eyepiece spacing to your
j until it is hand-tight.
- 18 -
e and turn the microscope
r anti-clockwise.