Accessories: Test leads (attached), holster, battery, and Users
Manual.
Safety: Meets EN61010-1:2001 Cat II 300V; Pollution Degree II,
Class 2; UL311
EMC: Meets EN50081-1, EN50082-1
P
EMC: This product complies with requirements of the
following European Community Directives: 89/336/EEC
(Electromagnetic Compatibility) and 73/23/EEC (Low Voltage) as
amended by 93/68/EEC (CE Marking).
However, electrical noise or intense electromagnetic fields in the
vicinity of the equipment may disturb the measurement circuit.
Measuring instruments will also respond to unwanted signals that
may be present within the measurement circuit. Users should
exercise care and take appropriate precautions to avoid misleading
results when making measurements in the presence of electronic
interference.
Electrical Specifications
Accuracies are indicated as ± % of full scale values at 23°C ± 5°C,
<75% RH.
DC Volts
Ranges: 2.5, 10, 50, 150, 300 V
Accuracy, all Ranges: ±5%
Input Impedance: 2 ke/V
AC Volts – Accuracies apply to sine wave inputs only
Ranges: 50, 150, 300 V
Accuracy, all ranges: ±5%
Input Impedance: 2 ke/V
DC Current
Ranges: 0.5, 10, 250 mA
Accuracy: ±5%
OL Protection: 200 mA/250 V ceramic fuse (PN FP150)
Resistance
Ranges: 5 ke, 500 ke
Accuracy, all ranges: ±5%
Battery Test
Battery Voltages: 1.5 V, 9 V
Accuracy: ±10% of good/bad line